World Library  


Add to Book Shelf
Flag as Inappropriate
Email this Book

Calibration Evaluation and Calibration Stability Monitoring of Fringe Projection Based 3D Scanners : Volume Xxxviii-3/W22, Issue 1 (26/04/2013)

By Bräuer-burchardt, C.

Click here to view

Book Id: WPLBN0004017133
Format Type: PDF Article :
File Size: Pages 6
Reproduction Date: 2015

Title: Calibration Evaluation and Calibration Stability Monitoring of Fringe Projection Based 3D Scanners : Volume Xxxviii-3/W22, Issue 1 (26/04/2013)  
Author: Bräuer-burchardt, C.
Volume: Vol. XXXVIII-3/W22, Issue 1
Language: English
Subject: Science, Isprs, International
Collections: Periodicals: Journal and Magazine Collection (Contemporary), Copernicus Publications
Historic
Publication Date:
2013
Publisher: Copernicus Publications, Göttingen, Germany
Member Page: Copernicus Publications

Citation

APA MLA Chicago

Breitbarth, A., Munkelt, C., Heinze, M., Bräuer-Burchardt, C., Notni, G., & Kühmstedt, P. (2013). Calibration Evaluation and Calibration Stability Monitoring of Fringe Projection Based 3D Scanners : Volume Xxxviii-3/W22, Issue 1 (26/04/2013). Retrieved from http://new.worldlibrary.net/


Description
Description: Fraunhofer IOF Jena, Albert-Einstein-Str. 7, 07745 Jena, Germany. In this work a simple new method for calibration evaluation and calibration stability monitoring of fringe projection based 3D scanners is introduced. This method is based on high precision point correspondence finding of fringe projection sensors using phase values in two perpendicular directions and epipolar geometry concerning calibration data of stereo sensors. The calibration evaluation method can be applied in the measurement process and does not require any additional effort or equipment. It allows the evaluation of the current set of calibration parameters and consideration of the stability of the current calibration over certain temporal progression. Additionally, the quality of distortion correction can be scored. The behavior of three fringe projection based 3D stereo scanner types was analyzed by experimental measurements. Results of the different types of scanners show that calibration may be stable over a long time period. On the other hand, suddenly occurring disturbances may be detected well. Additionally, the calibration error usually shows a significant drift in the warm-up phase until the operating temperature is achieved.

Summary
CALIBRATION EVALUATION AND CALIBRATION STABILITY MONITORING OF FRINGE PROJECTION BASED 3D SCANNERS

 

Click To View

Additional Books


  • Earth Observation in Support of Science ... (by )
  • Spectral Discrimination and Reflectance ... (by )
  • Validation of a Parametric Approach for ... (by )
  • The Design of Data Disaster Recovery of ... (by )
  • Measurement of Glacier Velocity at Pik L... (by )
  • Automatic Extraction of Road Surface and... (by )
  • Digital Camera Calibration Using Images ... (by )
  • Researches on the Land-use Change Detect... (by )
  • New Contributions on the Dome of the Pan... (by )
  • Research Advances on Radiation Transfer ... (by )
  • Land-based Mobile Laser Scanning Systems... (by )
  • Feature Descriptor by Convolution and Po... (by )
Scroll Left
Scroll Right

 



Copyright © World Library Foundation. All rights reserved. eBooks from World eBook Library are sponsored by the World Library Foundation,
a 501c(4) Member's Support Non-Profit Organization, and is NOT affiliated with any governmental agency or department.